The Havells Adjustable Thermal & Fixed Magnetic 3P MCCB 415V 400A 36KA IHLLSEB30400 is a high-quality molded case circuit breaker (MCCB) that is designed to protect electrical circuits from overload and short circuit faults. It has a rated current of 400A and a breaking capacity of 36kA at 415V. The MCCB is also equipped with an adjustable thermal release and a fixed magnetic release for added protection.
Features
- Rated current: 400A
- Breaking capacity: 36kA at 415V
- Adjustable thermal release
- Fixed magnetic release
- 3-pole design
- Compact and rugged design
- Easy to install and use
- Wide range of operating temperatures
- Complies with IS/IEC 60947-2 standards
Benefits
- Protects electrical circuits from overload and short circuit faults
- Prevents damage to electrical equipment and avoids downtime
- Improves safety and reliability of electrical installations
- Easy to use and maintain
- Value for money
Applications
The Havells Adjustable Thermal & Fixed Magnetic 3P MCCB 415V 400A 36KA IHLLSEB30400 is ideal for use in a wide range of applications, including:
- Industrial plants
- Commercial buildings
- Residential complexes
- Power generation and distribution facilities
- Infrastructure projects
How it works
The Havells Adjustable Thermal & Fixed Magnetic 3P MCCB 415V 400A 36KA IHLLSEB30400 works by monitoring the current flowing through the circuit. If the current exceeds the setpoint of the thermal release, the MCCB trips and disconnects the circuit from the power supply. This prevents the circuit from being overloaded and damaged.
The fixed magnetic release trips the MCCB when there is a sudden increase in current, such as during a short circuit fault. This protects the circuit from being damaged by the high current.
Installation and use
The Havells Adjustable Thermal & Fixed Magnetic 3P MCCB 415V 400A 36KA IHLLSEB30400 is easy to install and use. It is typically mounted on a DIN rail in a switchboard or panel. The MCCB is connected to the circuit and the power supply using the terminals provided.
Once the MCCB is installed, it is important to set the thermal release current trip point. The trip point should be set slightly above the normal operating current of the circuit. This will ensure that the MCCB trips only when the circuit is overloaded.
Maintenance
The Havells Adjustable Thermal & Fixed Magnetic 3P MCCB 415V 400A 36KA IHLLSEB30400 is a low-maintenance device. However, it is important to inspect the MCCB regularly for signs of wear and tear. The MCCB should also be tested periodically to ensure that it is functioning properly.
Reviews
There are no reviews yet